Open phased array integrated module EXPLORER

Share
 
 

Open phased array is an advanced radar system architecture that features resource virtualization, application software, and hardware building blocks. This system is capable of adapting to constantly changing combat tasks, working environments, and platforms, and is expected to become the mainstream development direction of the next generation phased array system, with broad application prospects in fields such as radar, communication, and electronic warfare.

 

Pulse generator

Voltage

100 -50 V1

Pulse shape

Negative square wave

pulse width

10-1000 ns (optional lower frequency)

Pulse width resolution

4 ns

Range of Launch Delay

0-40 µs

Launch delay accuracy

4 ns

Maximum PRF

20 kHz

 

receiver

Sampling accuracy

14 bits per channel

Gain range

12-110 dB

System bandwidth

50 kHz -20 MHz

Receiving delay range

0-40 µs

Receiving delay accuracy

5 ns

DDF

Up to 64 points

 

data processing

FIR filter

Up to 64 taps

Number of filters

15, customizable by users

Digital frequency

10 ns

Downsampling

50, 33, 25, 16.65, 14.28, 12.5 MHz...

Full record of A-scan data

support

The maximum number of scanned data points for A

PA mode 32768 points

The number of focusing rules

Maximum 4096

FMC Options

support

The number of data points scanned by A

4096 points in FMC mode

 

communication

Communication link

LAN 2xGb (TCP/IP)

Effective ultrasound data transmission efficiency

≥ 200 MB/s1

 

system

size

300x140x80 mm

weight

< 2.9 Kg

Number of channels (configuration)

128 Px / 128 Rx

The number of focusing rules

4096

FMC supports aperture size

128

A-scan depth

8, 16 bits

Temperature sensor

have

Open source SDK

Yes (complete documentation API)

Software development language

C++, C#, LabVIEW, MATLAB, Python...

operating system

Windows, Linux

Full focus acquisition

Support TFM PWI、ATFM、APWI...

3D focusing calculation of two-dimensional phased array probe

Support (optional)

AFM-API (Advanced API)

Includes TFM, real-time acquisition imaging (optional)

Installation Options

No tools required